Main Equipment
Solar Panel Mono
540 W, 2278×1134 mm, about 27–28 kg (check datasheet)
Converts sunlight into DC electricity. A 144 half-cut-cell mono panel is typical.
script script
A 45-part solar PV portfolio across equipment, structure, cable, protection, monitoring and spares — supported by project sizing for requirements from a few kW up to 400 kW and beyond.
Every rating shown is a catalogue starting point taken from the source data. Wattage, voltage and capacity labels are not a brand-specific guarantee — confirm the current datasheet and the project design before purchase.
Filter by family or system size. Select a part for its technical profile.
Main Equipment
540 W, 2278×1134 mm, about 27–28 kg (check datasheet)
Converts sunlight into DC electricity. A 144 half-cut-cell mono panel is typical.
Main Equipment
580 W, bifacial
Collects light from both front and back. Gains most on high-reflectance ground or ground-mount plants.
Main Equipment
5–110 kW, 3-phase, anti-islanding (IS 16221)
Grid-connected inverter that converts DC to AC. Used for bill-saving systems without batteries.
Main Equipment
5–10 kW, battery support
Manages grid, panels and battery together. Provides backup during outages.
Main Equipment
800 W (typically 2–4 panels per unit)
Mounted behind each panel with its own MPPT. Useful on shaded roofs.
Main Equipment
5–10 kWh, with BMS
Stores energy for night or outages. LiFePO4 is generally safer with a long cycle life.
Main Equipment
60 A MPPT
Controls battery charging from the panels in off-grid systems.
Main Equipment
12 V / 24 V
Ready-to-use small kit: panel, controller, cables.
Structure
GI, 1–100 kW
Galvanized frame that holds panels at the right angle on a roof.
Structure
GI, about 3 m
Frame that holds rows of panels on open ground, with foundations.
Structure
GI
Canopy over parking that carries panels. Gives shade and power.
Structure
Aluminium, 4.2 m
Long bar that holds the panels. Light and corrosion-resistant.
Structure
GI C-channel
Main support beam of the structure that the rails sit on.
Structure
Aluminium
Sits between two panels and clamps both.
Structure
Aluminium
Clamps the panel at the end of a row.
Structure
SS304, M8 / M10
Fasteners for structure joints. Must be corrosion-resistant.
Structure
M16, 300 mm
Anchors the structure into the concrete foundation. Critical under wind load.
Cable
Red, 4/6 mm², 1000–1500 V
Positive DC cable from the panels. UV-resistant solar grade.
Cable
Black, 4/6 mm², 1000–1500 V
Negative DC cable from the panels.
Cable
Copper/aluminium, 3-phase
Carries AC power from the inverter to the ACDB / main panel.
Cable
Green, minimum 6 mm² copper
Connects structure and equipment to the earth pit.
Cable
MC4 male, IP67
Male DC cable connector.
Cable
MC4 female, IP67
Female DC cable connector. Join male and female of the same make.
Cable
UV-resistant nylon, 300 mm
Binds cables and keeps them tight to the structure.
Cable
GI / FRP
Tray for laying and protecting cables.
Safety & Protection
With fuses and SPD, IP65
Combines several strings into one output.
Safety & Protection
DC, 1000–1500 V
DC-side box: fuses, DC MCB and SPD.
Safety & Protection
AC, 3-phase
AC-side box: MCB/MCCB and SPD.
Safety & Protection
Type 2, on DC and AC sides
Protects inverter and panels from lightning and surges.
Safety & Protection
DC rated, 1000 V
Breaker that trips on overload or short circuit in DC circuits.
Safety & Protection
DC fuse, 10–15 A
Blows on a short circuit to protect the string.
Safety & Protection
DC / AC isolator
Switch that isolates the circuit for maintenance.
Safety & Protection
Copper / copper-bonded, 14–16 mm, 3 m
Rod that carries current into the ground.
Safety & Protection
LPS, IS/IEC 62305
Carries a lightning strike safely down to earth.
Safety & Protection
GI / copper strip
Strip that connects earth pits and structure.
Safety & Protection
Pit cover
Cover over the earth pit, opens for testing.
Monitoring
RS485 / Ethernet
Sends inverter data to the internet.
Monitoring
WiFi / GPRS
Connects the inverter to Wi-Fi/GPRS for app monitoring.
Monitoring
Commercial, 3-phase
Measures total plant generation.
Monitoring
Bi-directional
Measures energy exported to and imported from the grid. Installed by the DISCOM.
Monitoring
CT coil
Steps down large current for the meter.
Spare Parts
Long handle
Brush for cleaning panels.
Spare Parts
Panel cleaning
Sprinkler for washing panels with water spray.
Spare Parts
MC4 spare kit
Spare set of MC4 connectors and crimping parts.
Spare Parts
Crimper + spanner, etc.
Tools for installation and maintenance.
References below are for orientation. Documents are shared for the exact product and scope before an order is confirmed.
IS 14086 (performance and safety; equivalent to IEC 61215 / 61730). BIS listing applies under the 2022 Quality Control Order — confirm the current certificate for the exact model.
IS 16221 Part 1 (general and anti-islanding) and Part 2 (safety). Grid code, anti-islanding and DISCOM approval must be confirmed for the model.
IS 3043:2018 (earthing), IEC 62548 (PV array) and IS/IEC 62305 (lightning). Final earth resistance and pit design are confirmed by a licensed engineer.
A model-specific datasheet is provided on request. Certificate issuer, scope and validity are checked before sharing.
No certification is claimed on this page. Certification status is confirmed only after a valid document covering the exact product, facility and scope is provided.
Policy changes by state and over time. Confirm the current rule on your DISCOM / SERC and MNRE site.
Policy figures are reproduced from the technical guide and public sources; they are not independently confirmed live and may change. Confirm current status before relying on them.
Commercial terms are confirmed per part, model and destination. Nothing here is a fixed published price or lead time.
Indicative planning figures for a rooftop or ground-mount plant.
Panels ship in manufacturer cartons; structure and cable are bundled per the dispatch plan.
Glass modules are fragile and need edge protection and careful handling in transit and on site.
Delivery scope, site access and unloading are confirmed per project and destination.
EPC and commissioning are planned with the project design, earthing and DISCOM approval.
Estimate panels, output and area from your target capacity.
Short answers on sizing, pricing, documents and support.
From small rooftop kits up to 400 kW and beyond. The catalogue spans the equipment, structure, cable, protection, monitoring and spares used across those sizes.
No. Prices and per-kW costs are not published. They are quoted on request per part, model and project scope.
No. They are catalogue labels taken from the source data. The model-specific datasheet must be checked before quoting or ordering.
The standards section lists compliance references for orientation only. Valid certificates are shared for the exact product and scope on request; none is claimed on this page.
Products are provided against a confirmed specification. Installation and commissioning are planned with an EPC partner and the project design.
From your electricity bill and sanctioned load, then a site survey and shadow analysis. The sizing calculator above gives an initial estimate.
Request a project assessment, ask for a datasheet or send a quotation enquiry for parts and systems.